Prodyn Current Transducers I-150 Series (1.50″ aperture)

Prodyn Current Transducers I-150 Series (1.50″ aperture)

With an internal aperture of 38.1 mm, the I-150 series bridges the gap between the I-125 series (ID = 31.75 mm) and the much larger I-262 series (66.5 mm).

The I-150-1HF is the first probe to be offered in the new housing and has similar performance characteristics to the high frequency I-125-1HF probe. It has a transfer impedance of 5 Ω and bandwidth from 1 kHz to 1 GHz (usable frequency range 50 kHz – 1 GHz).

This new I-150 housing will be offered for other current probes designs.

I-150-1HF Prodyn Current Probe

  • Model – I-150-1HF
  • Usable frequency range – 1 kHz – 1 GHz
  • Zt (Ω) – 5
  • Max Output Voltage (Vom) – 400
  • Saturation current (A) – 15.39
  • CW max average current (A) – 1.27
  • Peak current (A) – 72
  • Max pulse width (uS) – 0.42
  • Rep rate (kHz) – 0.74

    Contact Form