EN/IEC 61000-4-2 Ed2 & ISO 10605 Ed2 Compliant
SMART ESD simulator which supports all phases of the test (Pre to Post)
Items | ESS-S3011A specifications |
Polarity | Positive or negative |
Output voltage | 0.2 to 30.0kV +/-5% (30.5kV Maximum) 0.2 to 10kV: 0.05V step, 10.0 to 30.0kV: 0.1kV step |
Repetition cycle | 0.05s to 99.9s +/-10% / Manual 0.05s to 10.0s: 0.05s step, 10.0 to 99.9s: 0.10s step |
No. of time of discharge | 1 to 60,000 times /continuous |
Discharge mode | Contac discharge / Air discharge |
Radiation level mode | Normal mode / Extra mode |
Trigger mode | Gun trigger / Main unit trigger / External trigger |
Operation panel | Color LCD / Push-buttons (Partially lighting) |
Gun holder | Standard attached (to hold the discharge gun Model GT-30RA) |
Radiation mode select switch | Extra / Normal switching function built-in |
Discharge detection | Discharge detection function in air-discharge mode equipped |
Pre-checking function | Following 3 steps function equipped (by under operation. Not the calibration but just checking) SETP 1 High voltage output checking STEP 2 Withstanding voltage checking STEP 3 Discharge relay operation checking |
CR & Gun head checking | CR constant and gun head recognizable (with an indicator to prevent the wrong combination) |
IEC standard test mode | Contact discharge mode: 2.0, 4.0, 6.0, 8.0 kV step Air discharge mode: 2.0, 4.0, 8.0, 15.0 kV step |
Manual test mode | Contact/Air discharge mode: 0.20kV to 30.0kV Sweep function available Up to 50 units (test settings) storable. |
Sequence test mode | Seamless run of the selected test sequence No. of steps per one sequence: up to 22 steps No. of test sequences: up to 20. |
Warning lamp | Lights up while the HV circuitry is on. Blinks while discharges are in progress. |
Charging capacitor and resistance | 150pF +/-10%, 330 ohm+/-10% (built into Discharge Gun GT-30RA) |
Main unit charging resistance | 10M ohm (53M ohm for combination with Discharge Gun GT-30RA) |
AUX connector | D-SUB 15 pin, female connector Connection of Warning Lamp (optional) Connection of Automatic ESD Eliminator (optional) External interlock input External trigger input |
Optical communication connector | Optic connector for PC communication (serial interface) |
Power supply/ Power consumption | 100V to 240V AC, 50Hz/60Hz +/-10% 75VA |
Included accessories | Remote controller 13-00004A, Gun holder, Instruction manual |
Dimensions and weight | (W) 270 X (H)312 X (D)295 mm Approx. 7.0kg (gun holder excluded) , Approx. 7.5kg (gun holder included) |
tems | GT-30RA specifications |
Output voltage | 30.5kV Max |
Polarity | Positive or Negative |
Repetition cycle | 0.05s and over Note) Guaranteed value is 0.1s and over (330pF and under) |
Discharge mode | Contact or Air |
Charging resistor | Built-in CR unit |
Charge/Discharge capacitor & Discharge resistor | Built-in CR unit |
High voltage connector | Composite connector of high voltage and signal line (male) 。ハNoiseKen custom) |
Operation switch | Discharge trigger |
LED irradiator | White LED light built-in for irradiating EUT 。ハFocusing point is the tip) |
Included accessories | CR unit (150pf-330 ohm) 06-00073B Conical discharge tip 12-00007A Round discharge tip 12-00008A Instruction manual |
Dimensions and weight | (W) 83X (H) 217 X (D) 229 mm (projection excluded) Approx. 0.8kg (Cable and connector excluded) Approx. 10.8kg (Cable included, connecter excluded) |